Home     Latest News     About us     Contact us     Distributors     Cookies   
#
You are here > Products  » Metallic Adaptors & Reducers


Exd “Flameproof” & Exe Increased Safety Adaptors and Reducers

Redapt metallic adaptors and reducersRedapt AD-U and RD-U Series of Adaptors and Reducers provide a method of matching electrical threadforms on hazardous area approved equipment whilst ensuring the integrity and Ex approval of the installation is maintained.

Manufactured from hexagon material to facilitate easy installation, they are also supplied complete with a captive o-ring seal. The o-ring is located within a recess on the face of the product, helping to protect the o-ring from environmental damage and ensuring it is not displaced during installation.

Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size, to the entry thread of the enclosure.

Reducers are used where the thread size of the cable gland or entry device is smaller than the entry thread of the enclosure.

Redapt metallic adaptors and reducersRedapt Adaptors & Reducers are designed for hazardous area applications and are certified to protection concepts Exd “Flameproof” and Exe “Increased Safety” for use in Zone 1 and Zone 2 applications.

Approved to the latest international standards, adaptors and reducers can be supplied with ATEX (CENELEC), IECEx, and GOST-R hazardous area certificates.

In addition CSA approval certificates can be supplied to cover use in North American and Canadian Class I Division 1 and Class I Zone 1 applications.

Technical Data Table

Protection Method
Exd – Flameproof / Exe – Increased Safety
Ingress Protection Maintained IP66 / IP67 / IP68 to a depth of 2 metres
Impact Resistance
20 Nm (7Nm for Aluminium products)
Ambient Temperature Range
-50°C to 100°C
Materials
Brass CZ121, 316 Stainless Steel, Aluminium 6082, Mild Steel EN1A
Plating
Nickel, Electroless Nickel, Zinc, others on application
O-Ring Materials
Nitrile, Silicone, Viton, EPDM, Neoprene, others on application
Standards Approved To
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
CENELEC ATEX Approval

SIRA00ATEX1094X

IECEx Approval
IECEx SIR 12.0016X
GOST-R Approval

РОСС GB.ГБ06.В01251 – Russian
РОСС GB.ГБ06.В01251 – English
РОСС GB.ГБ06.В01251 Annex Document - English

CSA Approval
1248014 (LR 106084-2)
Installation Instructions

English
German - tbc
French - tbc

Russian - tbc

How To Order
Part Number System
Product Datasheet
Data Sheet Metallic Adaptors and Reducers

 

 

#