Exe “Increased Safety" Hexagon Head Stopping Plugs

Redapt Metallic  Hex Head Stopping PlugsRedapt’s PH-E Series of Hex Head Stopping Plugs provide a method of blanking off unused entries in hazardous area approved equipment whilst ensuring the integrity and Ex approval of the installation is maintained.

The PH-E Series of stopping plugs are designed to be installed from the outside of an enclosure and can be used in a threaded or un-threaded entry hole. An appropriate sized sealing washer can be used to ensure the required level of ingress protection is maintained.

Redapt’s Hex Head Stopping Plugs are designed for hazardous area applications and are certified to protection concept Exe “Increased Safety” for use in Zone 1 and Zone 2 applications.

Approved to the latest international standards stopping plugs can be supplied with ATEX (CENELEC), IECEx, and GOST-R hazardous area certificates.

In addition CSA approval certificates can be supplied to cover use in North American and Canadian Class I Division 2 and Class I Zone 1 applications.

Technical Data Table

Protection Method
Exe – Increased Safety
Ingress Protection Maintained
IP64
Impact Resistance
7Nm
Ambient Temperature Range
- 50° C to 100° C
Materials
Brass CZ121, 316 Stainless Steel, Aluminium 6082,
Mild Steel EN1A
Plating
Nickel, Electroless Nickel, Zinc, others on application
O-Ring Materials
None
Standards Approved To
IEC 60079-0, IEC 60079-1, IEC 61241-0, IEC 61241-1
CENELEC ATEX Approval
SIRA00ATEX3092 - English
SIRA99ATEX3092 - German
SIRA99ATEX3092 - French
IECEx Approval
T.B.C.
GOST-R Approval
РОСС GB.ГБ06.В00276 – Russian
РОСС GB.ГБ06.В00276 – English
CSA Approval
1248014 (LR 106084-2)